Engineered wood and fibre cement are both named in the 2024 Ontario Building Code (O. Reg. 163/24) as cladding materials, but the Code treats them differently.

What the Code actually says about each

For engineered wood (hardboard and OSB), the Code has dedicated subsections with specific rules. Hardboard siding must conform to ANSI A135.6 and be at least 9.5 mm thick where supports are not more than 400 mm apart or the wall is continuously sheathed, or 11.1 mm where supports are up to 600 mm apart; lapped strips need a gap of at least 5 mm at butted ends (2024 OBC, 9.27.9.). OSB cladding must conform to CSA O437.0, have all panel edges supported and treated with a primer or sealer, and have a 3 mm gap between panels (9.27.10.). The Code's 200 mm clearance above finished ground, and 50 mm above a roof, is for cladding adversely affected by moisture, and it names OSB and hardboard as examples (9.27.2.4.); ask the manufacturer and the City whether a given engineered wood product counts. There is also a 3 mm clearance required between hardboard or OSB cladding and door and window frames (9.27.9.5., 9.27.10.4.).

Fibre cement is named in the Code's scope (9.27.1.1.) and in the face-sealed cladding article (9.27.3.6.), but the Code contains no dedicated subsection for it, no material standard, no minimum thickness, and no specific gap or clearance rule. Its installation follows the general cladding articles plus the manufacturer's written instructions. So the manufacturer's written instructions govern the details.

The Code's 200 mm ground clearance applies to moisture-sensitive cladding such as untreated wood, plywood, OSB, waferboard and hardboard. We found no Code ground clearance rule for fibre cement; for that material, the manufacturer's instructions govern.

On cost, published Ontario contractor price pages from 2025 to 2026 show engineered wood installed at about $9 to $23 per square foot of wall, and fibre cement installed at about $10 to $25 per square foot. What moves either number: removal of old layers, trim, corners, what is found behind the existing siding, access and height, and disposal.

Both materials require a sheathing membrane (house wrap) conforming to CAN/CGSB-51.32-M beneath them, with joints lapped at least 100 mm and upper sheets overlapping lower sheets where applied horizontally (9.27.3.2., 9.27.3.3.). Both need flashing at horizontal junctions and at wall openings where the vertical distance from the bottom of the eave to the top of the trim is more than one-quarter of the eave's horizontal overhang (9.27.3.7., 9.27.3.8.). Both need sealant between the siding and adjacent door and window frames (9.27.4.).

Whichever you choose, check one quote line in particular: what the contractor will charge if damaged sheathing or framing is found once the old cladding comes off; ask for that rate in writing before the job starts.

Ottawa Siding Contractors

Want this done at your place?

Tell us about your siding and we'll send it to local Ottawa siding contractors, who reply by email. We send it out to local contractors for you. Free, no pressure.

Fields marked are required.

We won't call you. There's no phone box above because we don't ask for one — your estimate comes by email, on your time.

Request received We’ve sent your details to local Ottawa siding contractors. Interested contractors reply by email. A confirmation is on its way to your inbox.

Siding IQ -- Built from the Ontario Building Code, Ontario regulations and City of Ottawa sources and real construction experience. Answers are for informational purposes only and are not a professional assessment.

Ready to Get Quotes?

Find local siding contractors in Ottawa. Free matching, no obligation.

Find a Siding Contractor